| 型号规格:HS-150单路输出开关电源 | ||||||||||||
| ||||||||||||
| 型号 | HS-150-5 | HS-150-9 | HS-150-12 | HS-150-13.5 | HS-150-15 | HS-150-24 | HS-150-27 | HS-150-48 | ||||
| 输出 | 直流输出电压 | 5V | 9V | 12V | 13.5V | 15V | 24V | 27V | 48V | |||
| 输出电压容差(注3) | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ||||
| 额定输出电流(注5) | 30A | 16.7A | 12.5A | 11.2A | 10A | 6.5A | 5.6A | 3.2A | ||||
| 输出电流范围 | 0-30A | 0-16.7A | 0-12.5A | 0-11.2A | 0-10A | 0-6.5A | 0-5.6A | 0-3.2A | ||||
| 输出功率 | 150W | 150.3W | 150W | 151.2W | 150W | 156W | 151.2W | 153.6W | ||||
| 纹波及噪音(注2) | 150mVp-p | 180mVp-p | 180mVp-p | 180mVp-p | 180mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | ||||
| 直流电压可调范围 | ±10% | -12%,+15% | -12%,+10% | -12%,+11% | ±10% | -12%,+16% | -12%,+11% | ±10% | ||||
| 启动、上升、保持时间 | 100ms,50ms,20ms满载 | |||||||||||
| 输入 | 输入电压范围 | 88~132 VAC/176~264VAC 47~63Hz,由开关选择 248~370VDC | ||||||||||
| 交流输入电流 | 3.2A/115 V 1.6A/ 230 V | |||||||||||
| 效率 | 78% | 80% | 82% | 83% | 84% | 85% | 86% | 87% | ||||
| 冲击电流 | 冷启动电流35A/230VAC | |||||||||||
| 漏电流 | <3.5mA/240VAC | |||||||||||
| 保护 | 过载保护 | 110%~160% | ||||||||||
| 保护方式:切断输出 ,重新启动 | ||||||||||||
| 过电压保护 | 115%~135% | |||||||||||
| 保护方式:切断输出,重新启动 | ||||||||||||
| 环境 | 工作温度、湿度 | -10℃~+60℃;20%~90 %RH | ||||||||||
| 保存温度、湿度 | -20℃~+85℃;10%~95 %RH | |||||||||||
| 抗震性 | 10~500Hz,2G 10min./1周期,时长60分钟,各轴 | |||||||||||
| 安全 | 耐压性 | 输入输出间:1.5KVAC 输入与地:1.5KVAC 输出与地:0.5KVAC | ||||||||||
| 绝缘电阻 | 输入输出间,输入与地,输出与地: 100M Ohms/500VDC | |||||||||||
| 符合 | 安全标准 | 符合UL1012, UL1950,TUV EN60950 | ||||||||||
| EMC标准(注4) | 符合EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 | |||||||||||
| 其它 | 重量 | 0.8Kg | ||||||||||
| 包装 | 22pcs/18Kg/1.22CUFT | |||||||||||
| 备注 | 所有参数在未特别指明时,都是在230VAC电压输入,额定负载和25℃条件下测量所得值。 纹波和噪声电压是在20MHz带宽示波器带12英寸双绞线末端加0.1μ和47μ电容时测得。 容差是电压设定误差、电压调整率和电流调整率之总和。 本电源考虑做为一个器件安装在最终设备上,该设备必须重新确认它的EMC指标。 具体输出电流见输出降额曲线。 | |||||||||||